SolarPanelKits
Sizing Guide

How to Size a Solar Kit: A Simple Load Calculation, Worked Step by Step

Skip the guesswork. Follow one small-cabin example from a list of devices to a panel, battery and inverter size, with every step shown so you can swap in your own numbers.

10 min read Updated November 2026 SolarPanelKits Editorial Team
In this guide
  1. Why load math beats guessing by panel wattage
  2. Step 1: List your loads and daily watt-hours
  3. Step 2: Add the hidden overhead
  4. Step 3: Find your worst-month peak sun hours
  5. Step 4: Size the panels
  6. Step 5: Size the battery
  7. Step 6: Size the inverter and sanity-check
  8. Frequently asked questions

Key takeaways

  • Start with energy: wattage × hours per day for every device, plus inverter idle draw.
  • Size panels to your worst month of use, using monthly solar radiation from NREL PVWatts, not an annual average.
  • In our example, the same 1,520 Wh/day load needs about 700 W of panels in winter but only about 320 W in summer.
  • Battery size = daily Wh × days of autonomy ÷ usable depth of discharge; lead-acid needs a much bigger bank for the same usable energy.
  • Size the inverter by the watts running at the same time, and keep idle draw in mind before oversizing it.

The fastest way to buy the wrong solar kit is to pick one by panel wattage alone. A 400 W kit can be plenty for a summer weekend shed and badly short for a cabin you visit in January, even if you plug in exactly the same things. The fix is a load calculation: a short, honest list of what you run and for how long, turned into watt-hours and then into panels, battery and inverter. It takes about twenty minutes with a notepad. Below we walk through one complete example for a small cabin, using clearly labeled example wattages and real solar data guidance from NREL and the Department of Energy, so you can repeat it with your own numbers.

Why load math beats guessing by panel wattage

Most kit listings lead with panel wattage because it is the easiest number to print on a box. But panel watts only describe how much power the array can make under ideal test light. NREL's PVWatts documentation ties a panel's nameplate rating to a reference irradiance of 1,000 watts per square meter, which is bright, direct sun that your roof only sees for part of a clear day. What you actually need is energy (watt-hours) delivered every day, through every season you plan to use the system.

A load calculation flips the question around. Instead of asking "what can a 400 W kit run?", you ask "what do I run, and what does it take to cover that on my worst-month day?" The answer tells you three things at once: how many panel watts you need, how big the battery should be, and how large an inverter you need.

i
Good to know

Every wattage in the example below is an illustrative example value, not a measurement of any specific product. Use the nameplate or spec sheet of your own devices, or measure them with a plug-in usage meter.

Step 1: List your loads and daily watt-hours

The U.S. Department of Energy's formula for appliance energy is simple: wattage × hours used per day = daily energy use (divide by 1,000 if you want kWh). Find wattage on the device label or power adapter. If only amps are listed, multiply amps by volts. DOE notes that a nameplate wattage is the maximum the device draws, so labels usually overstate real use slightly, which is a safe direction to err.

Here is a worked example for a small weekend cabin or a well-used backyard office shed:

Load (example values)WattsHours/dayWh/day
LED lights (4 × 10 W)405200
Phone and tablet charging20360
Laptop604240
12V compressor fridge (45 W, cycling)458 (24 ÷ 3)360
Wi-Fi router1024240
Box fan306180
Total1,280 Wh

The fridge line uses a DOE rule of thumb: because refrigerators cycle on and off, you can estimate running hours by dividing the time it is plugged in by three. A 12V fridge's real duty cycle depends on its insulation, the outside temperature and how often you open it, so check the manufacturer's stated daily consumption if one is published. That figure is better than any rule of thumb.

✓
Tip

Don't forget "always on" loads. DOE points out that standby power adds up. A router, a security camera or an inverter left idling runs all 24 hours, so even a small wattage becomes a big daily number.

Step 2: Add the hidden overhead

Your devices aren't the only thing drawing power. The system itself uses some too, and a sizing plan that ignores it comes up short in winter.

Inverter idle draw

An inverter uses power just by being switched on, even with nothing plugged in. Look for "no-load current" or "idle consumption" on the spec sheet. In our example we'll assume 10 W of idle draw, running 24 hours: 10 × 24 = 240 Wh/day. If you switch the inverter off overnight, or run DC loads like the fridge directly from the battery, this number drops.

That brings the example to 1,280 + 240 = 1,520 Wh/day that the battery has to deliver.

Conversion and storage losses

Energy is also lost on the way from panel to battery to device. Two published figures give us reasonable starting assumptions:

We'll use both in the array calculation in Step 4. If you are using lead-acid, swap 0.92 for 0.80 and you'll see the array size climb.

Step 3: Find your worst-month peak sun hours

A "peak sun hour" is a way of expressing a day's sunlight as the equivalent number of hours at that 1,000 W/m² reference level. Solar radiation data for PV is usually given in kilowatt-hours per square meter, so a location that receives 4 kWh/m² on a panel in a day has about 4 peak sun hours.

The number that matters for an off-grid kit is your lowest month of use, not your annual average. The Department of Energy notes that Denver receives nearly three times more solar energy in June than in December. Penn State's off-grid design course (based on standard stand-alone PV practice) sizes systems around the "critical design month," the month with the worst combination of low sun and high load.

  1. Open NREL PVWattsGo to pvwatts.nrel.gov and enter your address. It uses NREL's National Solar Radiation Database for typical-year weather.
  2. Enter your array detailsPut in a rough system size, the tilt you plan to use and the direction the panels will face. Tilt changes winter results a lot.
  3. Read the monthly solar radiation columnPVWatts reports average daily plane-of-array irradiance for each month. That value is your peak sun hours for that month.
  4. Pick the lowest month you'll actually use the systemA summer-only camp can size to May through September. A year-round cabin sizes to December or January.

For the example we'll assume a worst-month value of 3.0 peak sun hours and a best-month value of 6.0. These are illustrative numbers. Yours could be higher or lower, so look them up.

!
Watch out

PVWatts estimates are based on a typical weather year. A real year can run noticeably sunnier or cloudier, so leave headroom rather than sizing exactly to the estimate.

Step 4: Size the panels

The array formula puts the pieces together:

Panel watts = daily Wh ÷ (peak sun hours × (1 − system losses) × battery efficiency)

For the example, using the worst month:

1,520 ÷ (3.0 × 0.86 × 0.92) = 1,520 ÷ 2.37 ≈ 641 W

Round up to a real panel combination, roughly 700 W (for example, two 350 W panels or seven 100 W panels). Now compare the same load in the best month:

1,520 ÷ (6.0 × 0.86 × 0.92) ≈ 320 W

Summer-only use

About 350–400 W

Covers the example load from late spring through early fall at roughly 6 peak sun hours.

Year-round use

About 700 W

Covers the same load at 3 peak sun hours. That is double the panels for the same appliances.

In between

Cut the winter load

Unplug the fridge, switch off the inverter overnight, or add a generator for the darkest weeks instead of buying extra panels.

This is exactly why two people with the "same" appliances can need very different kits. Season matters as much as the load list.

Check the controller current

Divide array watts by battery voltage to estimate charge current. At 12V (12.8V nominal for LiFePO4), 700 W ÷ 12.8 ≈ 55 A. At 24V (25.6V), it's about 27 A. Victron's Wiring Unlimited guide recommends raising system voltage before reaching for very thick cables, since doubling voltage halves current. This example points toward a 24V system with an MPPT controller rated comfortably above 27 A, with input voltage limits that suit your panel wiring. See our guide to MPPT headroom for the details.

MPPT solar charge controllersConfirm the max PV input voltage and the rated output current for your battery voltage.
Check prices on Amazon →

Step 5: Size the battery

The battery has to cover nights plus any cloudy stretch you want to ride through without a generator. Penn State's stand-alone sizing method uses this approach: multiply daily energy by days of autonomy, then divide by the allowable depth of discharge.

Battery Wh = daily Wh × days of autonomy ÷ usable depth of discharge

With 2 days of autonomy (an example choice for a non-critical cabin):

ChemistryUsable DoD usedMathBattery size
LiFePO480%1,520 × 2 ÷ 0.803,800 Wh (≈148 Ah at 25.6V)
Lead-acid (AGM or flooded)50%1,520 × 2 ÷ 0.506,080 Wh (≈253 Ah at 24V)

Why those depth-of-discharge figures? Victron rates its LiFePO4 cycle life at 80% depth of discharge, and Trojan Battery generally recommends discharging its lead-acid batteries 20–50% of rated capacity. Read more in our LiFePO4 vs lead-acid guide.

Cold reduces usable capacity for both chemistries. Penn State's method applies a temperature and discharge-rate derating factor, so if your battery lives in an unheated space, add margin or keep it somewhere insulated.

24V LiFePO4 batteriesCompare usable watt-hours, continuous discharge current and low-temperature charging protection.
Check prices on Amazon →

Step 6: Size the inverter and sanity-check

The inverter is sized by power (watts at one moment), not energy. Add up everything that might run on AC at the same time. In the example, if the lights, laptop, fan, router and chargers are all on at once: 40 + 60 + 30 + 10 + 20 = 160 W. The 12V fridge runs on DC, so it doesn't count here.

A small pure sine wave inverter covers this easily. Size up for anything you'll add later, like a power tool or coffee maker (check its nameplate), and allow for motor start-up surge. Don't oversize by a huge margin, though: bigger inverters often idle at a higher draw, and that comes straight back into Step 2.

Your sizing summary

Prefer to skip the arithmetic? Our solar system sizing calculator runs the same steps.

Plug-in watt metersMeasure what your devices actually draw instead of relying on nameplate maximums.
Check prices on Amazon →

Frequently asked questions

How do I calculate my daily watt-hours for a solar kit?

Multiply each device's wattage by the hours you use it per day, then add the results. This is the formula the U.S. Department of Energy uses for appliance energy. Include always-on loads like routers and the inverter's own idle draw, and use a usage meter or the manufacturer's consumption rating for cycling appliances like refrigerators.

What are peak sun hours and where do I find mine?

Peak sun hours express a day's sunlight as the equivalent hours at 1,000 watts per square meter, the reference level used for panel ratings. NREL's free PVWatts calculator reports average daily solar radiation for each month at your address, tilt and orientation; that monthly value is your peak sun hours.

Should I size my solar kit for winter or summer?

Size for the lowest-sun month you actually plan to use the system. A summer-only camp can size to summer sun, while a year-round cabin should size to December or January. In our example, the winter requirement was roughly double the summer one for the same load.

How many days of battery autonomy do I need?

It depends on how critical your loads are and how cloudy your area gets. Two days is a common starting point for a non-critical cabin. Standard stand-alone design practice adds more days for critical loads, or pairs a smaller battery with a backup generator.

Why does my battery need to be bigger than my daily use?

You need to cover more than one day if you want to ride through cloudy weather, and you shouldn't routinely drain a battery to zero. Dividing by usable depth of discharge (about 80% for LiFePO4 in Victron's ratings, and commonly 50% or less for lead-acid per Trojan's guidance) gives the nameplate size you need.

Turn your numbers into a parts list

Our kit buying guide shows what complete kits include and leave out, so you can match a kit to the panel, battery and inverter sizes you just calculated.

Read the kit buying guide →

Sources

  1. Estimating Appliance and Home Electronic Energy Use — U.S. Department of Energy
  2. Solar Radiation Basics — U.S. Department of Energy
  3. PVWatts Calculator — National Renewable Energy Laboratory (NREL)
  4. PVWatts Version 5 Manual — NREL
  5. Stand-Alone System Sizing (AE 868) — Penn State College of Earth and Mineral Sciences
  6. 12.8V Lithium Iron Phosphate Batteries Smart: Datasheet — Victron Energy

This guide is for general information only and is not electrical, engineering or legal advice. Always follow the manufacturer's instructions, the National Electrical Code (NFPA 70) as adopted in your area, and local permitting rules, and hire a licensed electrician where your jurisdiction requires one. Product availability, specs and prices change; verify them on the listing before you buy. As an Amazon Associate we earn from qualifying purchases.